Monkey Cortisol (Cortisol) ELISA kit instruction manual

Monkey Cortisol (Cortisol) ELISA kit is for research use only.
Detection range: 96T
7μg / L -200μg / L
purpose of usage:
Monkey Cortisol (Cortisol) ELISA kit is used to determine the content of Cortisol in monkey serum, plasma and related liquid samples.
Experimental principle This kit uses the double antibody sandwich method to determine the level of Cortisol in the specimen. Coat the microplate with purified monkey cortisol (Cortisol) antibody to make a solid-phase antibody, add cortisol (Cortisol) to the monoclonal antibody-coated microwells in turn, and then combine with HRP-labeled cortisol (Cortisol) antibody To form an antibody-antigen-enzyme-labeled antibody complex. After thorough washing, the substrate TMB is added for color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with Cortisol in the sample. Use a microplate reader at
The absorbance (OD value) was measured at a wavelength of 450 nm, and the concentration of monkey cortisol (Cortisol) in the sample was calculated by a standard curve.
Monkey Cortisol (Cortisol) ELISA kit composition
1 30 times concentrated washing solution 20ml × 1 bottle 7 stop solution 6ml × 1 bottle
2 Enzyme label reagent 6ml × 1 bottle 8 standard (400μg / L) 0.5ml × 1 bottle
3 Enzyme label coated plate 12 wells × 8 strips 9 standard dilutions 1.5ml × 1 bottle
4 Sample diluent 6ml × 1 bottle 10 instructions 1 copy
5 Developer A solution 6ml × 1 bottle 11 2 sealing film
6 Developer B solution 6ml × 1 / bottle 12 sealed bag 1 specimen requirement
1. Specimens are extracted as soon as possible after collection, and extraction is performed according to relevant literature, and experiments should be conducted as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided
2. Samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity.
Steps
1. Dilution of standard products: This kit provides one original standard product. The user can perform dilution in a small test tube according to the following chart.
200μg / L No. 5 standard 150μl original standard added 150μl standard dilution
100μg / L No. 4 standard 150μl No. 5 standard added 150μl standard dilution
50μg / L No. 3 standard 150μl No. 4 standard added 150μl standard diluent
25μg / L No. 2 standard 150μl No. 3 standard added 150μl standard diluent
12.5μg / L No. 1 standard 150μl No. 2 standard added 150μl standard diluent
2. Add sample: set up blank wells separately (the blank control wells do not add samples and enzyme-labeled reagents, the rest of the steps are the same), standard wells,
Sample hole to be tested. Accurately add 50μl of the standard on the enzyme-coated plate, add 40μl of sample diluent to the sample well, and then add 10μl of the sample to be tested (the final dilution of the sample is 5 times) Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix.
3. Incubation: seal the plate with the sealing film and incubate at 37 ° C for 30 minutes.
4. Mixing solution: dilute 20 times concentrated washing solution with distilled water 20 times and reserve
5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with the washing liquid, let it stand for 30 seconds, then discard, repeat 5 times and pat dry.
6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well.
7. Incubation: The operation is the same as 3.
8. Washing: The operation is the same as 5.
9. Color development: add 50μl of developer A to each well, and then add 50μl of developer B, mix gently, and develop color at 37 ℃ in the dark
15 minutes.
10. Termination: Add 50μl of stop solution to each well to stop the reaction (at this time the blue will turn to yellow).
11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.

Summary of operating procedures:
1. Prepare reagents, samples and standards
2. Add the prepared samples and standards, and react at 37 ℃ for 30 minutes
3. Wash the plate 5 times, add enzyme-labeled reagent, and react at 37 ℃ for 30 minutes
4. Wash the plate 5 times, add color developing solutions A and B, and react at 37 ℃ for 10 minutes
5. Add stop solution
OD value within 6.15 minutes
7. Calculation

The calculation takes the concentration of the standard as the abscissa and the OD value as the ordinate, and draws a standard curve on the coordinate paper.
The corresponding concentration of OD value is found from the standard curve; then multiplied by the dilution factor; or the linear regression equation of the standard curve is calculated from the concentration of the standard and the OD value, and the OD value of the sample is substituted into the equation to calculate the sample concentration, and then multiplied The dilution factor is the actual concentration of the sample.
Precautions
1. The kit should be taken out of the refrigerated environment and equilibrated at room temperature for 15-30 minutes before use. If the enzyme-coated plate is unsealed after opening, the strip should be stored in a sealed bag.
2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing.
3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples.
4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the substance to be tested in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please dilute it with a certain multiple (n times) of the sample diluent and then determine it. Please multiply the total dilution for the calculation Multiple (× n × 5).
5. The sealing film is limited to one-time use to avoid cross-contamination.
6. Please keep the substrate away from light.
7. Strictly follow the instructions, and the test results must be determined by the microplate reader.
8. All samples, washing liquids and various wastes should be treated as infectious agents.
9. The components of different batches of this reagent shall not be mixed.
10. If there is any difference with the English manual, the English manual shall prevail.
Storage conditions and validity period
1. Kit storage :; 2-8 ℃.
2. Validity: 6 months

 All the Compostable Shopping Bags can be fully degraded, and have passed the American ASTM-D6400 and EU EN13432 compostable certification Standard test. Our Compostable Bags are made of 100% biodegradable resin as raw materials, free of plastic, non-toxic and harmless.

Bury the compostable shopping bags in the soil, or bury them in the environment with microorganisms.

The compostable bags can degrade 100% into carbon dioxide and water in 3 months and become organic 

fertilizer without white pollution.

compostable shopping bags

Compostable Shopping Bags

Compostable Shopping Bags,Compostable Waterproof Shopping Bags,biodegradable reusable bags

Ningbo ECO Biodegradable Technology Co., Ltd , https://www.chinabiodegradable.com