New mold incubator is easy to operate

霉菌培养箱.jpg

1. When the incubator is being transported, it is forbidden to invert and lay flat at more than 45 degrees.

2. Never change the setting value frequently during use so as to avoid overload caused by frequent start of the compressor and affect the service life of the equipment.

3. When lighting is not needed in the box, the lighting switch should be placed in the “off” position so as not to affect the temperature of the upper layer and prolong the service life of the lamp.

4. The unit is equipped with two sets of fuses. If there is a fault during operation, please cut off the power supply first, check whether the fuse is in good condition, and then check other parts.

5, in order to maintain the appearance of the equipment, do not use the corrosive solution to wipe the appearance, the box can be wiped with a dry cloth or alcohol to keep the box clean.

6. When the equipment is not in use, keep it dry and cut off the power.

7. To ensure that the temperature inside the box is even, always check whether the axial fan in the box is running normally. During the experiment, the contents of the box should not be over-crowded. Do not block the outlet of the fan. Leave space for the circulation of the air inside the box.

8, do not touch, collision box temperature, humidity probe, causing temperature and humidity out of control.

9. If the equipment fails, you should ask professional personnel to repair or contact the factory sales department. Users should not repair it at will.

Usage: Fill the sink with pure water according to the instructions, insert the ultrasonic atomizer power cord into the rear plate diagram (2) “Humidifier control socket”, and insert a soft plastic sleeve into the ultrasonic atomizer outlet At the same time, the other end is inserted into the “air inlet” of the top plate diagram (3), and the ultrasonic atomizer has been connected to the host. Plug in the power of the host computer and press the power switch “1” on the right side of the panel. Press the digital display on the instrument to indicate that the device is in the working state. Refer to the control panel diagram for setting parameters. The setting method is as follows:

(a) The temperature/time key can be switched between temperature and time:

1) Temperature setting: Press the temperature/time key, the temperature setting indicator of the instrument is on. Press SET key to enter SV state, then press ∨ or ∧ key to change the temperature setting value to the desired temperature (minimum 0°C), and finally press Set key to save the setting value in the microcontroller