To operate a constant temperature and humidity test chamber properly, it's essential to follow scientific procedures. Correct usage not only extends the equipment’s lifespan but also ensures accurate and reliable test results. After purchasing the equipment, users should thoroughly study the operation manual and fully understand its functions to maximize efficiency and performance.
Proper operation of environmental testing equipment is crucial for long-term stability and durability. When used correctly, these devices can maintain consistent conditions over time, supporting precise data collection and ensuring that tests are conducted at a scientifically sound level. Based on years of research and production experience, Zhongbao has developed extensive knowledge in operating constant temperature and humidity chambers effectively. Here are some key guidelines to help you optimize your testing process:
1. **Understand the Test Requirements**: Before conducting any environmental test, familiarize yourself with the sample characteristics, test conditions, and procedures. Also, know the technical specifications of the equipment being used. Pay special attention to the controller functions and always read the user manual carefully to avoid errors that could damage samples or compromise data accuracy.
2. **Select Appropriate Equipment**: Choose the right test chamber based on the sample type and size. Ensure that the sample volume does not exceed recommended limits relative to the chamber’s effective capacity. For heat-generating samples, keep the volume under 10% of the chamber’s capacity. For non-heat-generating samples, the limit is around 20%.
3. **Use the Right Mediums**: If the test requires adding a medium, such as water in a damp-heat chamber, make sure to use the correct type. For example, resistivity should be controlled for proper humidity regulation. A cost-effective and convenient option is pure water, which offers similar properties to distilled water.
4. **Handle Wet Bulb Gauze Properly**: In wet-heat chambers, the wet bulb gauze must be of a specific type—usually a special "wet ball gauze" made from linen. Using the wrong material can affect humidity readings. The gauze should be 100mm long, tightly wrapped around the sensor, positioned 25–30mm from the humidity cup, and fully immersed in the water reservoir to ensure accurate control and measurement.
The constant temperature and humidity test chamber consists of several key components: the chamber body, air circulation system, refrigeration unit, heating system, and humidity control mechanism. The air circulation system often includes adjustable airflow directions, while the humidification system may use either boiler-based or surface evaporation methods. Cooling and dehumidification typically rely on standard air conditioning refrigeration, and heating is usually achieved through electric heating elements or direct electric furnaces. Humidity can be measured using dry and wet bulb methods or directly via sensors, and the control interface may separate or combine temperature and humidity controls.
HUMGINE products include: Constant Temperature and Humidity Test Chamber, High and Low Temperature Test Machine, Clean Oven, Blast Drying Oven, Constant Temperature Drying Oven, Moisture Proof Cabinet, Nitrogen Oven, High and Low Temperature Box, Incubator.