Operation procedure and operation method of impact tester in use

The operation procedures and methods for using impact testing machines have become increasingly widespread across various industries. However, many companies still struggle to make effective use of these machines after purchasing them. A major challenge is the lack of proper training and clear guidelines for employees on how to operate the equipment correctly. As the application of impact testing machines grows in popularity, it's crucial that companies not only acquire the machines but also ensure their staff are properly trained. Unfortunately, many organizations fail to implement standardized operating procedures, leading to underutilization or improper use of the equipment. To address this issue, technical experts from the manufacturer of ring test equipment have prepared a detailed guide to help users understand and operate the testing machine effectively. If you're new to this kind of equipment, you might be wondering, "Why should we use a testing machine? What is the purpose of using one?" This article aims to answer those questions and provide practical steps for safe and efficient operation. Here’s a step-by-step guide to using an impact testing machine: First, connect the power cable and turn on the power switch. Next, select the appropriate force range based on the sample being tested. Attach or remove the pendulum as needed and adjust the cushion valve handle accordingly. Choose the suitable jaws according to the shape of the sample and place them into the jaw base. On the drum of the recorder, roll up the recording paper (square paper) if required for data collection. Start the oil pump power head and slowly open the oil delivery valve to raise the testing platform by 10 mm, then close the valve. If the platform is already in the raised position, there's no need to start the oil pump—just close the fuel supply valve. Secure one end of the specimen into the upper jaw. Turn on the oil pump and adjust the pointer aiming plate to zero. Then, start the lower jaw motor, which will automatically raise or lower the jaw to the correct height. Fix the other end of the specimen into the lower jaw, ensuring the specimen remains vertical during the test. Place the brush on the recorder and prepare the drawing form if you need to record results. Finally, based on the required loading speed for your experiment, slowly open the oil delivery valve to begin the loading process. Always monitor the machine carefully and follow safety protocols throughout the test. By following these steps, users can maximize the benefits of the impact testing machine and ensure accurate, reliable results. Proper training and understanding of the operation procedures are essential for getting the most out of this valuable testing equipment.

Other Shape Lip Gloss Case

We have many different kinds of other shape LIP GLOSS CASE.Any injection color is avaliable for the empty plastic cosmetic lip gloss case.Spray painting/UV coating/metallized are also available for the lip gloss case.

MOQ

12.000pcs

Delivery time

50-55days

Material

AS,ABS

color

Injection color,spray coating color,UV and metalizing color

logo

Silk screan and hot staping

Packing

paper carton

Place of Origin

Zhejiang

We promise out standing service tailored to meet your demands. Our products are favored by many customers all over the world and are sold in Europe, North America, South America and Asia.

We are looking forward to your E-mail and establishing cooperative relationship with you! We would provide professional lip gloss case with good services for you.

LG-374CLG-356


Lip Gloss Case 8ml,Custom Lip Gloss Case,Brand Lip Gloss Case,Modern Design Lip Gloss Case

ims Packaging Limited , https://www.ims-cosmetic-packaging.com